BBP Operations Status: Click Here to View

Temperature Sensors and Transmitters

Temperature sensors and transmitters feature significant advances over their direct wired counterparts. Eliminate special cabling requirements and simplify engineering and maintenance while enabling advanced diagnostics. Wireless temperature solutions make measurement easier and more economical.

Featured Solutions

  • STZ

    The STZ is a Functional Safety, Dual Input, Smart HART® temperature transmitter that can configure quickly and easily to accept a wide array of sensor and analog devices. These 2-wire transmitters provide an isolated and linear 4-20mA output proportional to the input. The signal is ready for direct interface with HART or non-HART based Safety System, DCS, PLC and other computer0based SCADA systems. Mounting choices include field enclosures, compact connection heads and a high-density, DIN-style housing.

    Part of Moore Industries’ FS Functional Safety Series, the SIL 2 and SIL 3 capable STZ Functional Safety Dual Input Smart HART® Temperature Transmitters for your SIS (Safety Instrumented System) configures quickly and easily to accept a single or dual input from a wide array of sensors and analog devices located in hazardous and nonhazardous areas:
    • 14 RTD Types
    • 9 Thermocouple Types
    • Resistance and Potentiometer Devices
    • Direct Millivolt Sources
    These 2-wire (loop-powered) transmitters provide an isolated and linear 4-20mA output proportional to the input. This signal is ready for direct interface with HART or non-HART based Safety System, DCS, PLC and other computer-based SCADA systems. FMEDA (Failure Mode Effects and Diagnostic Analysis) reports are available with the required safety data to ensure that the STZ meets the requirements of each Safety Instrumented Function (SIF).

    Features:

    exida certified to IEC 61508:2010. Certified by exida to IEC 61508 for systematic integrity up to SIL 3 and for random integrity up to SIL 2. This means that an STZ is approved for single use in Safety Instrumented Systems (SIS) up to SIL 2 and in a redundant architecture (1oo2, 2oo3, etc.) up to SIL 3.
    Comprehensive FMEDA certified safety data. Upon request, exida-certified FMEDA data is available for a functional safety practitioner to use in determining the STZ’s applicability in specific safety-related applications.
    AIS option allows direct connection of sensors located in hazardous locations without the requirement of an intrinsically safe barrier. This option has blue terminals, DIN housing only.
    Dual sensor input for Backup and Failover Protection, Average and Differential measurement and Low or High Select.
    Device Intelligence including Sensor Drift and Corrosion Detection, Smart Range Alarms, Highavailability option, and Input Simulation capability.
    HART 7 compliant with exception-based reporting and dynamic variable mapping.
    HART Access Control. To prevent unauthorized or accidental reconfiguration of the STZ while it’s performing it’s safety function, it has an added security feature to allow users to set HART communication into a Read Only or Off mode.
    Input-to-output analog accuracy of up to ±0.014°C (±0.025°F)* is the absolute best in the industry.
    20-bit input resolution delivers exceptional digital accuracy of ±0.1°C (±0.18°F) with all Pt RTDs or up to ±0.05°C (±0.09°F)* for Pt1000 RTDs.
    HART & DTM Programmable with user-oriented basic configuration for fast and accurate setup. HART configurable via any HART handheld configurator or HART compatible host. Additionally program or monitor with any FDT compliant host or program, such as PACTware, utilizing our DTM.

    To learn more about the STZ and other Moore Industries products available at BBP, click here.

    DOWNLOAD BROCHURE
  • tdz3-thz3

    The THZ3 & TDZ3 are dependable and accurate Smart HART® temperature transmitters with dual input sensors that simplify your operations. Their advanced features give you far more control over your temperature measurements. Each sensor is individually selectable and programmable HART or DTM. Mounting choices include field enclosures, compact connection heads and a high-density DIN-style housing. Learn more about temperature products from BBP.

    DOWNLOAD BROCHURE
  • YTA50 Temperature Transmitter

    The YTA50 is a head or DIN rail mount temperature transmitter with a single input. The single input accepts thermocouples, RTD, Ohms or a DC millivolt source. All inputs are linearized and converted in to an industrial standard 4 to 20 mA DC output for transmission to your system. YTA50 is the choice for your monitoring applications.

    YTA50 features include:

    • 4 to 20 mA DC analog output
    • 16 Input Types
    • Head Mount or DIN Rail Mount

    YTA50 Overview

    Microprocessor-based sensing technology ensures high accuracy and stability.

    • Accuracy: Dependent on sensor selected
    • Cold Junction Compensation: yes
    • Input: single input
    • Output: Two wire 4 to 20 mA DC analog
    • Mounting: DIN form B Head Mount -or- DIN Rail Mount (with adapter)
    • Weight: 0.11 lb.
    • Certifications: ATEX, FM

    Variety of sensor inputs

    The type of sensor input is user-selectable: RTD, Thermocouple (T/C), DC Voltage, or Resistance.

    Learn more about the temperature sensors and transmitters that BBP offers here.

    DOWNLOAD BROCHURE
  • temperature-sensors-and-transmitters

    YTA610 Temperature Transmitter

    The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART® 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure. By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work. The YTA610/YTA710 temperature transmitters bring unique value to temperature measurement while meeting a range of user needs. The essential YTA610 temperature transmitter is our base solution. It offers accurate temperature measurement (Pt100: ±0.14°C / ±0.25°F) and diagnostics critical to keep the process running well. The YTA610 is available with HART® 7 or FOUNDATION™ Fieldbus ITK 6. Learn more about temperature products from BBP.

    DOWNLOAD BROCHURE

  • YTA70

    Like the YTA50, the YTA70 is a 2-wire analog temperature transmitter that outputs a simple 4 to 20 mA output that corresponds to the temperature measured. However, it adds HART 5 (Code -E) or selectable HART 5 or HART 7 (Code -J) digital communication. The YTA70 delivers all the benefits found in the YTA50 while adding HART digital protocol communication. The HART protocol allows you to conveniently configue the transmitter using the latest FDT/DTM technology. The YTA70 is the choice for all your control applications. YTA70 features include 4 to 20 mA DC Analog Output, HART 5 Digital Protocol Output (-E version), Selectable HART 5/7 Digital Protocol Output (-J version), 17 Input Types, and Head Mount or DIN Rail Mount. Learn more about temperature products from BBP Sales.

    DOWNLOAD BROCHURE
  • YTA70P Temperature Transmitter

    The YTA70P is a panel mount type of temperature transmitter. The YTA70P delivers the characteristics of both converters and transmitters. It has a space-saving design that offers low cost installation. The HART 7 protocol allows you to conveniently configure the transmitter using the latest FDT/DTM technology. HART 7 benefits include long tag, enhanced burst mode, and event notification. The YTA70P is the choice for rail-mounted control applications.

    YTA70P Features:

    • 4 to 20 mA DC Analog Output
    • HART® 7 Digital Protocol Output
    • 17 input types
    • Rail-mounts

    Overview

    • Accuracy: Dependent on sensor slescted
    • Cold Junction Compensation: yes
    • Input; single input
    • Output: 4 to 20 mA DC analog with HART 7 Digital Protocol
    • Mounting: DIN Rail: DIN EN60715 – 35 mm
    • Weight: 0.33 il.
    • Certifications: General Purpose only

    Variety of Sensor Inputs

    The type of sensor input is user-selectable: RTD, Thermocouple (T/C), DC Voltage, or Resistance.

    Learn more about temperature products from BBP.

    DOWNLOAD BROCHURE
  • temperature-sensors-and-transmitters

    YTA710 Temperature Transmitter

    The YTA710 Temperature Transmitter provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20mA DC analog signal or Fieldbus digital signal. HART® 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure. By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work. The YTA610/YTA710 temperature transmitters bring unique value to temperature measurement while meeting a range of user needs. YTA710 is our premium solution. It offers unsurpassed accuracy (Pt100: ±0.10°C / ±0.18°F) and the ultimate diagnostics for demanding applications. The YTA710 is available with HART® 7 or FOUNDATION™ Fieldbus ITK 6. Learn more about temperature solutions from BBP.

    DOWNLOAD BROCHURE

SEE ALL SOLUTIONS

Sales Inquiries & Customer Support

(800) 299-4142